The operability and recognizability of the operation switch are improved
The operation switch (setting switch and mode switch) has been changed to an easy-to-press mechanism. In addition, the color of the operating switch has changed from black to light gray, which improves its visibility in dimly lit places.
peculiarity
The operability and recognizability of the operation switch are improved
The operation switch (setting switch and mode switch) has been changed to an easy-to-press mechanism. In addition, the color of the operating switch has changed from black to light gray, which improves its visibility in dimly lit places.
The operability and recognizability of the operation switch are improved
Reduce the difference in the body of the fiber optic sensor and feel a different sense of stability!
The combination of the FX-500 series and ultra-high-quality optical fibers reduces the airframe difference of light intake to 1/4 of the conventional level. Approximation values are displayed even after the amplifier is replaced, enabling true digital management.
Reduce the difference in the body of the fiber optic sensor and feel a different sense of stability!
Quality that surpasses common sense of standard fiber optics! Ultra-high-quality optical fibers were born.
The new construction method of our factory and the quality management system of "manufacturing". Fiber optic head made of new material. Dramatically improve the basic performance of optical fibers!
Quality that surpasses common sense of standard fiber optics! Ultra-high-quality optical fibers were born.
25μs of high-speed response
The FX-500 Ver.2 equipped with the SENTRION sensor engine further improves productivity with the industry's fastest high-speed response.
Fastest 25μs in the industry
Even when it comes to small workpiece inspections that require a reaction diameter fiber, it can be applied to a higher detection distance than the previous fastest mode, regardless of whether the speed is increased or not.
Equipped with a HYPR mode for long-range sensing
This is 5.7 times larger than conventional products. In particular, long-distance detection is achieved using ultra-high-precision small-diameter optical fibers.
Equipped with a HYPR mode for long-range sensing
The reflective sensor FD-NFM2 is 5.7 times larger than conventional products.
*As of September 2009, the results of our survey
Reduced strain, keen detection, different acuity!
Equipped with SENTRION, the core component of the inspection, and a thorough improvement in the S/N ratio, it is possible to detect subtle changes in light that were previously undetectable.
■Detection of workpieces with small light differences even at long distances [H-02 mode]
Detection of workpieces with small light differences even from a long distance [H-02 mode]
Avoiding saturation for keen detection [H-01 mode]
Avoiding saturation for keen detection [H-01 mode]
Flat panel display with a wide field of view
The large-screen, high-contrast, high-brightness 7-segment display is not covered and can be viewed clearly from multiple viewing angles.
Flat panel display with a wide field of view
In order to make it easier to understand, the amount of light entering is adjusted and set and displayed uniformly
By using the display adjustment settings, you can correct any displayed value. Several units are valid under the same conditions.
In order to make it easier to understand, the amount of light entering is adjusted and set and displayed uniformly
It can be stably detected in the long and short term
Stable amount of light emitted
The "4-element light-emitting diode", which was the first in the industry to be equipped with a stable amount of light, has become the industry's standard. The FX-500 Ver.2 series also uses this diode and an "APC (Auto PowerControl)" circuit that achieves short-term stability when the power supply is on.
Set the benchmark value tracking period
In order to track changes in light volume caused by long-term environmental changes (dust, etc.), the amount of light entering can be checked at any period and the reference value can be automatically reset. This contributes to long-term stable inspections and reduced maintenance man-hours.
Ideal for Preventive Protection Self-Diagnostic Output [FX-502(P) / FX-505(P)-C2]
The FX-502(P)/FX-505(P)-C2 can set output 2 as a self-diagnostic output. When teaching the reference value of output 1, output 2 is linked and the setting is performed by changing the remaining reference value of any setting. It detects bending of optical fibers and dirt caused by dirt and reduces the amount of light, and outputs it in the form of an alarm.
■Reduced detection light (used in dusty environments)
Reduced detection light (used in dusty environments)
The self-diagnosis function has been added to the benchmark value tracking function, which is effective.
Stable detection and ECO are available, and light power & gain setting are available
When the light is too strong and saturated, the amount of light emitted can be adjusted to the appropriate amount of light automatically (AUTO) without changing the reaction time of the amplifier. As a result, the optimal S/N ratio enables stable detection and energy-saving effects such as reducing the emitting current.
Built-in control functions No controller required, effectively saving wiring and reducing costs ■Equipped with logic operation function
■Equipped with logic operation function
Three logic operations (AND, OR, XOR) can be performed using only the fiber optic sensor, and three operations can be selected for output 1. There is no need for a dedicated controller, which can save wiring and reduce costs.
■Equipped with 5 types of timer functions
A wide range of timer controls can be performed using only fiber optic sensors.
Timer time: about 0.05ms~32s
Switch-on · disconnection delay, turn-on delay · ONE SHOT is only equipped with output 1.
Launched Monitored Current Output Type [FX-505(P)-C2]
A simulated current of 4~20mA can be output to the numerical value of the incoming light, so it is possible to monitor the detected object.
Smooth process changeovers are realized through 8 databases
The number of databases that can be used to store amplifier setting conditions in the main memory has been increased to eight. Set conditions can be saved and loaded, so it is possible to reduce the need for changeovers at production sites where a wide variety of products are produced.
Improving work efficiency through remote operation based on external input [FX-502(P) /FX-505(P)-C2]
Output 2 can be switched to an external input*. Actions are performed by external signals such as PLC, which improves work efficiency.
*The FX-502(P) can be used by switching the external input to output 2.
■A function that can be input externally
Fully automatic/limit/2-point correction Display adjustment settings
Loading/Saving Databases Logic Algorithms (Native Only)
Stop Casting the Copy Function Locking (This Machine Only)
The overall adjustment is carried out by the optical communication function
The optical communication function allows the entire data of the current setting to be copied and saved to all amplifiers connected to the right. This makes it possible to smoothly perform tasks such as sensitivity adjustment when changing production and changing amplifiers.
images/pic19.jpg
There is no distinction between host and slave
The amplifier body is not divided into the main engine and the sub-unit. The mother cable is used separately from the sub cable. This reduces man-hours and costs for amplifier inventory management.
There is no distinction between host and slave
Network communication is possible
The SC-GU3 series communication unit for open networks can be connected to open networks CC-Link IE Field/CC-Link/DeviceNet/EtherCAT. PLC, computer and other monitoring instruments can be connected and set.
※ CC-Link IE Field and CC-Link are trademarks of Mitsubishi Electric Corporation, and CC-Link is managed by the Association.
DeviceNet is an ODVA (Open DeviceNet Vender Association, Inc.) Registered trademark.
EtherCAT is a registered trademark of Beckhoff Automation GmbH.
wiring
Be sure to perform wiring and installation work with the power supply cut off.
Please note that applying voltage that exceeds the rated range or is directly connected to the AC power supply may cause damage or burnout accidents.
Please note that a short circuit in the load or incorrect wiring may cause damage or burnout accidents.
Avoid wiring in parallel with high-voltage and power lines, or using the same conduit. Otherwise, it will malfunction due to electromagnetic induction.
Please check the fluctuation of the power supply so that the power input does not exceed the rated range.
When using commercially available switching regulators, be sure to ground the frame ground (F.G.) terminals of the power supply.
When using equipment (switching regulators, inverter motors, etc.) that is a source of interference in the vicinity of the mounting part of this product, be sure to ground the frame ground (F.G.) terminals of the equipment.
Be sure to use a one-touch cable (sold separately) for the cable. In addition, when extending the cable, the total length can be extended to 100 m by using a cable with a cross-sectional area of 0.3 mm2 or more. However, to avoid interference, keep the wiring as short as possible.
Do not apply stress such as stiffening, bending, or pulling to the lead part of the cable and optical fiber.
other
This product is developed and produced for use in an industrial environment.
In strong electromagnetic fields, it may not be able to perform at full capacity.
The U-LG and HYPR with the reaction time setting have a higher sensitivity than other modes, so they are susceptible to external interference. Please check the usage environment before using it.
When using, avoid the transition state when the power is turned on (H-SP, FAST, STD: 0.5s, LONG, U-LG, HYPR: 1s).
Do not use outdoors.
Do not use in places with a lot of vapor, dust, etc.
Do not allow direct contact between the product and organic solvents such as thinners or strong acids, alkalis, oils, and greases.
It cannot be used in flammable or explosive atmospheres.
Do not disassemble, repair or modify the product without authorization.
This product uses EEPROM. EEPROM has a lifetime and cannot be taught more than 1 million times

Copy product links