Easy-to-use 2 digital screens
Two digital screens are available, allowing you to check the reference value, the amount of light entering the light, and various settings at the same time, making it extremely operable.
Easy-to-use 2 digital screens
Commercially available connectors are used to reduce processing preparation time & maintenance models
Since the use of commercially available connectors significantly reduces the cost of processing the connector and the preparation time for processing after the purchase of the sensor. It is possible to use the DP-100 series of digital pressure sensors, the PM-64 series of miniature photoelectric sensors, and connector components.
Commercially available connectors are used to reduce processing preparation time & maintenance models
Commercially available connectors are used to reduce processing preparation time & maintenance models
Space-saving Slim 9 mm wide
It is a slender specification with a width of 9 mm. Thinner than existing fiber optic sensors. There is not much difference when used for a single unit, but the difference can be very significant when used for multiple units.
Space-saving Slim 9 mm wide
Improves long-term stability
The projection element adopts the "4-element light-emitting diode" of the standard specifications of Panasonic's digital optical fiber sensor. This ensures a stable amount of light delivered over a long period of time.
Improves long-term stability
Simple operation with a clear operating system
The operating system of the DP-100, a digital pressure sensor that has been well received since its launch, is adopted. There are three types of settings: "RUN mode", "SET mode", and "PRO mode", depending on the level of the setting content, and the setting operation is simple and straightforward.
Simple operation with a clear operating system
Quick code entry function that is easy to set up [RUN mode]
The sensor can be set by simply entering a pre-set "code (number)" to set the sensor. Even if you change the settings by mistake, you can simply enter the code and it will be back to normal immediately. Even when using a phone, you can check the code (number) smoothly. Technical support is also easily available for overseas customers.
Quick code entry function that is easy to set up [RUN mode]
Simple teaching with ON/OFF button [SET mode]
Simply press the ON button at the position or state you want to detect, and press the OFF button in other cases to teach the setting. This saves time in judging the difference between ON when light enters and ON when shading.
■Teaching is possible without workpieces.
Limit the teaching function
By teaching the state of no workpiece (a state in which the amount of light entering is stable), it is possible to set the "standard value". It is convenient for detection of background objects and detection of small objects.
In addition, teaching can be done with external input.
Simple teaching with ON/OFF button [SET mode]
Elimination of deviations in the display of the amount of light entering GETA function [PRO mode]
Even with the same inspection, there are deviations in the digitized values of the individual fiber amplifiers. Although there is no problem with the inspection itself, it can also cause concern for the operator. With the GETA function, it is possible to correct to any value, so it is possible to eliminate deviations in the display and easily create work procedure books.
Elimination of deviations in the display of the amount of light entering GETA function [PRO mode]
Reduced maintenance man-hours and equipped with a reference value tracking interval setting function [PRO mode]
In order to track changes in the amount of light emitted due to long-term changes in the environment (dust, etc.), the amount of light entering can be checked at any period and the reference value can be automatically reset. This helps to reduce maintenance man-hours.
Reduced maintenance man-hours and equipped with a reference value tracking interval setting function [PRO mode]
Adjustable light emitting function for stable detection of small objects and transparent objects [SET mode]
When the light level is saturated, such as close-up detection, transparent objects, or small objects, the amount of light emitted by the sensor can be reduced to achieve stable detection. This function makes it easy to set up inspections that were previously required to change the fiber and set distance. In addition, in the past, it was possible to set only one level of light reduction, but now it is possible to set four types of settings with three levels + automatic setting. (from a part produced in December, 2007.) )
Adjustable light emitting function for stable detection of small objects and transparent objects [SET mode]
Mutual Interference Prevention & Flood Flashing Confirmed in Settings [SET Mode]
The maximum number of units that can prevent mutual interference □ the standard FX-101 □ and long-range FX-102 is 3 and 4, respectively. When the anti-interference is set, the projection flashes light, so the optical fiber of the setting is clear at a glance. In addition, it is not necessary to mount the amplifier as close to each other as before, and it can perform its function even if there is a distance between the amplifiers.
Mutual Interference Prevention & Flood Flashing Confirmed in Settings [SET Mode]
Externally configurable sensor [PRO mode]
Emission stop, limited teaching, automatic teaching, 2-point teaching, ECO, and light level testing can be set with external inputs. In addition, it is possible to store the benchmark values to be taught. (Note 1) Note 1: Based on the product manufactured in December 2007, there are adjustments in the storage of light input test and benchmark value2.
Externally configurable sensor [PRO mode]
Digital Display Reversal Setting Function [PRO Mode]
The direction of the digital display can be reversed according to the direction in which the amplifier is mounted.
Digital Display Reversal Setting Function [PRO Mode]
Reference value allowance setting function with clear detection allowance [PRO mode]
The balance of the reference value relative to the current amount of light can be checked by the flashing of the digital display.
Reference value allowance setting function with clear detection allowance [PRO mode]
Reduction of man-hours and human error Setting the Copy Function [PRO Mode]
By attaching the fiber optic sensors to the main fiber optic sensor one by one, the settings of the main sensor can be copied by data communication. When multiple optical fiber sensors are set in the same setting, it is possible to prevent failures caused by setting errors, and only a small change to the work instruction is required when changing the design of the device.
Reduction of man-hours and human error Setting the Copy Function [PRO Mode]
It can be installed freely without accessories
When attaching a DIN rail, it can be directly mounted through a through hole on the side of the body. In the case of direct installation, only one unit is installed or installed on the running unit, so it can be installed accurately without deviation.
It can be installed freely without accessories
Standard and long-distance products are available
There are two types of products: standard type and long-distance type, which have different reaction times and detection distances. It can be used according to the application.
Standard and long-distance products are available
It can save power consumption
After setting, if the key is not operated for about 20 seconds, the digital display will turn off, and the power consumption will be controlled to less than about 600mW. (720mW or less when illuminated)

Copy product links
Long by picture save/share
